CyFlow CD58 APC (RUO)

品番 AX001125
抗体名 Anti-Hu CD58 APC,MEM-63
包装単位 100 tests
濃度 -
推奨使用量 -
容量 1 ml
関連製品
(アイソタイプコントロール)
Mouse IgG1 APC (AB294043)
反応性|交差吸着 Human | Pig レーザー Red
抗原 CD58, LFA-3 最大蛍光波長 660 nm
クローン MEM-63 最大励起波長 650 nm
ホスト Mouse 標識/Format APC
アイソタイプ IgG1 研究分野 Immunophenotyping
クローナリティ monoclonal アプリケーション

-

Anti-Hu CD58 APC,MEM-63

特異性

The mouse monoclonal antibody MEM-63 recognizes CD58 antigen, a 40-70 kDa glycoprotein distributed over many tissues, leukocytes, erythrocytes, endothelial cells, epithelial cells and fibroblasts.

抗原情報

CD58 (LFA-3) is an immunoglobulin family adhession molecule expressed by both hematopoietic and non-hematopoietic cells (often on antigen presenting cells) and serving as ligand of CD2. This interaction is important for T cell-mediated immunity. CD58 is expressed in transmembrane form and in GPI-anchored form; the later is constitutively associated with protein kinases whereas the transmembrane form activates kinase activity upon triggering. CD58 is a powerful tool for detection of minimal residual disease in acute lymphocytic leukemia, and for evaluation of liver damage related with hepatitis B.

利用方法

The reagent is designed for Flow Cytometry analysis of human blood cells. Recommended usage is 10 µl reagent / 100 µl of whole blood or 10^6 cells in a suspension. The content of a vial (1 ml) is sufficient for 100 tests.

保存方法

Avoid prolonged exposure to light. Store in the dark at 2-8°C. Do not freeze.

安定性情報

Do not use after expiration date stamped on vial label.

レファレンス

• Ariel O, Kukulansky T, Raz N, Hollander N: Distinct membrane localization and kinase association of the two isoforms of CD58. Cell·Signal. 2004·Jun; 16(6):667‑73. <·PMID:·15093607·>
• Bayas MV, Schulten K, Leckband D: Forced detachment of the CD2‑CD58 complex. Biophys·J. 2003·Apr; 84(4):2223‑33. <·PMID:·12668431·>
• Sheng L, Li J, Qi BT, Ji YQ, Meng ZJ, Xie M: Investigation on correlation between expression of CD58 molecule and severity of hepatitis B. World·J·Gastroenterol. 2006·Jul·14; 12(26):4237‑40. <·PMID:·16830383·>
• Veltroni M, De Zen L, Sanzari MC, Maglia O, Dworzak MN, Ratei R, Biondi A, Basso G, Gaipa G: I‑BFM‑ALL‑FCM‑MRD‑Study Group: Expression of CD58 in normal, regenerating and leukemic bone marrow B cells: implications for the detection of minimal residual disease in acute lymphocytic leukemia. Haematologica. 2003·Nov; 88(11):1245‑52. <·PMID:·14607753·>
• Kishimoto T, Goyert S, Kikutani H, Mason D, Miyasaka M, Moretta L, Ohno T, Okumura K, Shaw S, Springer TA, Sugamura K, Sugawara H, von dem Borne AEGK, Zola H (Eds): Leucocyte Typing VI. Garland·Publishing·Inc,·New·York. 1997; 1‑1342. <·NLM·ID:·9712219·>

Available Safety Data Sheets

CyFlow™ 抗体SDS(日本語)

Available Technical Data Sheets

CyFlow™ CD58 APC (MEM-63) AX001125 TDS (US)